Extend the advantages of Panasonic PLCs with certified safety-related functions
|
|
FP-Safe controllers can be used to realize the safety-related functions required by the new Machinery Directive (2006/42/EC). The controllers achieve Safety Integrity Claim Limit 3 (SIL CL3) according to EN 62061, one of the harmonized standards under the new Machinery Directive.
The value of Panasonic?s safety solution lies in its comprehensive diagnostics. FP-Safe controllers and FP-series PLCs can be easily connected via RS232C, and the programming software FPWIN Pro contains a function block that reads diagnostic information from FP-Safe Controllers and transmits it to FP-series PLCs. Hence, customers not only know the execution status of an emergency stop, but also about which one was executed and where. Customers benefit from easier error detection, quicker maintenance and reduced machine down-time.
The FP-Safe controllers are freely configurable. The safety-related functions are predefined in the intuitive software tool ?FP-Safe Configurator?, which also visualizes the wiring of sensors and actuators, parameter settings for all safety-related components and signals, etc. Safe access control, program validation, and project verification mechanisms are implemented within the FP-Safe hardware and FP-Safe Configurator so that any unauthorized change is blocked and an error message issued.
|
 |
 |
|
FP-Safe series lineup
|
 |
 |
|
FP-Safe Controller with Transistor I/O Expansion Unit and Motion Monitoring Unit
|
|
Part number AFSCPM3012 This combination contains 30 redundant digital inputs, 4 positive switching, redundant outputs and 17 freely configurable outputs. In addition, 2 inputs available for 2 incremental measuring systems.
|
 |
 |
|
FP-Safe Controller with Relay Expansion Unit and Motion Monitoring Unit
|
|
Part number AFSCRM2215 This combination contains 22 redundant digital inputs, 4 positive switching, redundant outputs, 7 freely configurable outputs, 2 inputs for 2 incremental measuring systems and 4 safety relay outputs.
|
 |
 |
|
FP-Safe Controller with Relay Expansion Unit and Transistor I/O Expansion Unit
|
|
Part number AFSCRP2418 This combination contains 24 redundant digital inputs, 4 positive switching, redundant outputs, 13 freely configurable outputs and 4 safety relay outputs.
|
 |
 |
|
FP-Safe Controller with Relay Expansion Unit, Motion Monitoring Unit and Transistor I/O Expansion Unit
|
|
Part number AFSCWH3020 This combination contains 30 redundant digital inputs, 4 positive switching, redundant outputs, 17 free configurable outputs, 2 inputs for 2 incremental measuring systems and 4 safety relay outputs.
|
 |
 |
|
Cables
|
|
- Connecting cable between FP-Safe controller and FP-series PLC via COM port (3-pin), 0.5m
Part number CABMODPLC111D
- Connecting cable between FP-Safe controller and FP-series PLC via COM port (9-pin), 0.5m
Part number CABMODPLC211D
- Connecting cable between FP-Safe controller and FP-series PLC via tool port (mini-DIN), 0.5m
Part number AFS8TP
- Programming cable for FP-Safe controller, Sub-D (9 pin, male), 3m
Part number AFS8PG9
|
 |
 |
|
FP-Safe Configurator
|
The software tool FP-Safe Configurator works with Windows XP, Vista and Windows7 and requires a minimum of 512MB RAM. Hardware configuration, circuit diagram and rack diagnosis comprise the three main user tabs in the configurator. The software can be downloaded free of charge. If you cannot start the FP-Safe Configurator after installation, please update the Jave Runtime Environment on your computer: http://www.java.com.
|
 |
 |
|
Sistema library from Panasonic
|
|
Panasonic developed a library for you so that you can assess the risks for your machine using our products as simply as possible. You can download Panasonic's Sistema library, which is available in German and English. After you have imported the library into the Sistema program, all necessary component data for subsystems are available to you so that you can perform a comprehensive risk assessment.
|
 |
 |
|
Download the Sistema library from Panasonic
|
|
|
|